logo

Detalhes dos produtos

Created with Pixso. Para casa Created with Pixso. produtos Created with Pixso.
Conjunto de geradores a diesel Perkins
Created with Pixso.

AP200 144 kW 180 kVA Perkins Diesel Generator Set | Aike Power Factory Direct

AP200 144 kW 180 kVA Perkins Diesel Generator Set | Aike Power Factory Direct

Nome da marca: AIKE POWER
Número do modelo: AP200
MOQ: 1
Preço: Negotiate
Condições de pagamento: L/C,T/T
Capacidade de abastecimento: 1000 conjunto/m
Informações pormenorizadas
Lugar de origem:
China
Certificação:
ISO
Detalhes da embalagem:
Embalagem industrial à prova de umidade, base com estrutura de aço reforçada, caixas de madeira em c
Habilidade da fonte:
1000 conjunto/m
Descrição do produto
AP200 144kW 180kVA Perkins Diesel Generator Set | Prime 144kW / Standby 160kW

  • Prime Power: 144kW (180kVA) | Standby Power: 160kW (200kVA)
  • Engine Brand & Model: Perkins 1106A-70TAG3 6-cylinder turbo intercooled
  • Alternator: AIKE AP200 Brushless Alternator, THD < 2% Pure Sine Wave
  • Standard Controller: Deepsea DSE6020 AMF Control Panel
  • Frequency & Voltage: 50Hz, 400/230V 3 Phase 4 Wire
  • Ambient Temperature Range: -40℃ ~ 55℃, Custom 5000m High Altitude Version Available
  • Two Optional Versions: Open Frame / Soundproof Silent Canopy
Perkins Authorized Engine Supplier
CE ISO8528 Certified
15 Months Global Warranty
Factory Direct Supply
Worldwide Spare Parts Support
1. Product Overview

The AP200 180kVA Perkins diesel generator set is a heavy-duty industrial standby power unit independently developed by Aike Power, matched with original UK Perkins 1106A-70TAG3 turbocharged intercooled engine and self-excited brushless AP200 alternator with pure sine wave output.

Equipped with multi-grade Deepsea intelligent control system, it supports auto start, automatic mains failure transfer, multi-unit parallel operation and remote communication monitoring. Two structural options (open frame / soundproof silent canopy) are available to cover construction mining, hospital critical backup, commercial complex, off-grid plateau and factory emergency power supply scenarios.

Every AP200 genset undergoes full-load aging testing before delivery, fully compliant with ISO 8528, IEC and CE international standards, featuring stable continuous operation, low fuel consumption and outstanding harsh environment adaptability.

✅ Low THD Pure Sine Wave Power Output
✅ Original Perkins Reliable Power Engine
✅ Wide Range Harsh Environment Compatibility
✅ Low Vibration & Energy Saving Compact Design
2. 6 Core Competitive Advantages of AP200 Perkins Generator
2.1 Ultra-Stable Pure Sine Wave Alternator Output

Matched with self-developed AIKE AP200 brushless alternator with H-class insulation and IP23 dust & splash protection grade. Optimized star winding design limits total harmonic distortion below 2%, steady-state voltage regulation within ±1%.

The smooth pure sine wave current brings no waveform distortion, capable of stably driving all types of nonlinear loads including medical precision instruments, PLC control systems, frequency converters and server data center equipment. Tested alternator efficiency reaches up to 93.1% to reduce power loss during long-term operation.

2.2 Original Perkins 1106A-70TAG3 Industrial Engine

Powered by authentic UK Perkins 6-cylinder inline turbo intercooled engine, bore × stroke 105mm × 135mm, total displacement 7.01L. Mechanical governor system realizes precise fuel injection control, standby engine gross power reaches 177kW.

With mature 16:1 compression ratio design, the engine owns strong cold start performance under -40℃ low temperature. Complete lubrication & cooling system (16.5L oil capacity, 21L coolant capacity) extends overhaul cycle, reducing long-term maintenance frequency and cost for global clients.

Fuel consumption data under standard working condition:

100% PRP: 41.2 L/h | 75% PRP: 30.9 L/h | 50% PRP: 20.6 L/h

2.3 Powerful Harsh Environment Adaptability

The AP200 genset runs reliably under -40℃ ~ 55℃ wide temperature range with reinforced cold start auxiliary system, perfectly adapting to frigid polar regions, tropical high-humidity coastal areas and sandstorm mining zones.

Standard model supports stable operation under altitude ≤1500m; customized plateau modification version is available for 5000m high altitude areas with low power derating. Optional supporting accessories: water jacket preheater, water-oil separator for extreme low-temperature working sites.

2.4 Energy Saving, Low Vibration & Low Noise Design

Equipped with high-performance rubber anti-vibration mounts and rigid integrated steel base frame, the compact integrated structure effectively cuts mechanical vibration and running noise. Matched with industrial silencer and ripple flexible exhaust pipeline to suppress exhaust noise.

The optimized Perkins combustion system controls fuel consumption at a low level under all load ratios, greatly lowering long-term operation expenditure for industrial projects, while exhaust emission indicators meet international industrial environmental standards.

2.5 High Operation Economy & Easy Global Maintenance

Whole unit adopts standardized modular layout with highly universal spare parts, simplifying daily maintenance and global accessory procurement. The original Perkins engine enjoys global official after-sales spare parts network, no difficulty in component replacement worldwide.

The matching dry air filter, fuel filter and oil filter adopt general international specifications, clients can purchase replacement parts locally without long lead time, effectively reducing project downtime loss.

2.6 Multi-Layer Full Safety Protection System

Built-in main circuit breaker to block overload & short-circuit risks instantly. The Deepsea control panel integrates full automatic shutdown protection functions: low lubrication oil pressure, high coolant temperature, over-speed, under/over voltage, frequency deviation alarm & protection.

Complete safety guard covers fan belts, dual 12V starting batteries and anti-backfire exhaust structure, effectively avoiding unexpected equipment damage and operation safety hazards for long-time unattended running.

4. Complete AP200 Technical Data Sheet 
4.1 Overall Genset Main Parameters
Item Specification
Model AP200
Prime Power 144kW / 180kVA
Standby Power 160kW / 200kVA
Rated Frequency 50Hz
Rated Rotate Speed 1500 RPM
Rated Output Voltage 400/230V, 3 Phase 4 Wire
Power Factor 0.8 Lagging
Standard Applicable Altitude ≤1500m
Ambient Operating Temperature -40℃ ~ 55℃
Open Frame Dimension (L×W×H) 2550 × 930 × 1670 mm
Silent Canopy Dimension (L×W×H) 3590 × 1150 × 2050 mm
4.2 Perkins 1106A-70TAG3 Engine Detailed Spec
Engine Parameter Data
Manufacturer PERKINS (UK Original)
Model 1106A-70TAG3
Cylinder Layout Inline 6 Cylinders
Displacement 7.01 L
Bore × Stroke 105mm × 135mm
Compression Ratio 16:1
Aspiration Turbocharged & Intercooled
Governor Type Mechanical Governor
Cooling Mode Water Cooling
Coolant Capacity 21 L
Lubrication Oil Capacity 16.5 L
Electrical System 12 VDC
Standby Gross Engine Power 177kW
4.3 AIKE AP200 Brushless Alternator Spec
Alternator Item Parameter
Brand & Model AIKE POWER AP200
Phase Quantity 3 Phases
Power Factor 0.8
Bearing Type Single Bearing
Pole Number 4 Poles
Insulation Class H Class
Protection Degree IP23
Excitation Mode Brushless AVR Automatic Voltage Regulator
Connection Type Star Connection
No-Load Total Harmonic Distortion < 2%
Rated Standby Power 200kVA
Alternator Efficiency 93.1%
4.4 Optional Deepsea Control Panel Comparison
  1. DSE6020 Standard Panel: Single unit auto start, AMF mains protection, real-time data monitoring & basic fault alarm
  2. DSE7320 Upgrade Panel: Mains signal detection, USB/RS485/RS232 remote communication, expandable I/O ports
  3. DSE8610 Synchronizing Panel: Multi-unit parallel operation, automatic load sharing, 250 running event storage log
5. Standard Configuration & Optional Custom Upgrade Parts
5.1 Standard Equipped Accessories

Safety fan guard, belt-driven cooling fan, radiator assembly, dry air/fuel/oil filter set, main circuit breaker, dual 12V starting batteries, ripple flexible exhaust pipe, industrial muffler, anti-vibration shock mounts, rigid integrated steel base frame.

5.2 Custom Optional Upgrade Parts 
  1. Engine Auxiliary Parts: Water jacket preheater, water-oil separator, engine oil preheater, external automatic battery charger
  2. Alternator Auxiliary Parts: Anti-condensation space heater, PMG permanent magnet excitation system, winding temperature sensor
  3. Fuel & Enclosure System: Integrated daily fuel tank, automatic fuel filling system, rainproof canopy, silent rental canopy, mobile trailer chassis
  4. Electrical Control System: ATS automatic mains transfer switch, ABB brand circuit breaker, wireless remote monitoring control panel
6. Wide Application Scenarios
  1. Construction Site Temporary Emergency Power Supply
  2. Mining & 5000m High Altitude Industrial Power Station
  3. Hospital & Data Center Critical Life-Support Backup Power
  4. Shopping Mall, Hotel & Commercial Building Standby Power Unit
  5. Remote Village, Off-Grid Agricultural & Aquaculture Projects
  6. Factory Production Line Continuous Emergency Power Backup
AP200 silent generator sets are used in extremely cold regions.
7. Global Certifications & Compliance Standards

All AP200 Perkins generator sets pass mainstream international industry certifications, fully meeting global tender project access requirements:

  • Genset General Standard: ISO 8528, CE
  • Engine Test Standard: ISO 3046, BS 5514, DIN 6271
  • Alternator Electrical Standard: BS EN 60034, IEC 34, NEMA MG1-32, VDE 0530
8. Aike Power Factory Strength & Strict Production Testing

As an official authorized Perkins power unit manufacturer, Aike Power owns complete independent production workshop and dedicated full-load test laboratory. Every finished AP200 genset undergoes full-load aging test, pure sine waveform detection, high-low temperature simulation inspection before factory delivery.

Factory customization support: Global multi-standard voltage customization (380/220V, 415/240V, 440/254V), OEM brand logo printing, bulk container integrated delivery.

9. Global Warranty & After-Sales Service Support

Unified standard warranty policy (whichever expires first):

  1. 15 months counting from factory shipment date
  2. 12 months after on-site installation completion
  3. 1000 accumulated running working hours

Global after-sales service network: Local authorized distributors provide global spare parts supply, remote controller online debugging guidance, generator operation & maintenance technical training for project teams.

10.  Frequently Asked Questions
Q1: What’s the difference between prime power and standby power of AP200?

A: Prime power 144kW is continuous long-duration stable running power; standby power 160kW only applies to short-time emergency peak load, cannot operate continuously under full standby power rating.

Q2: Can AP200 generator work normally at 5000 meters altitude?

A: Standard unit adapts altitude below 1500m; we provide customized plateau modification version with adjusted fuel injection parameters to reduce power deration for 5000m extreme high-altitude working environments.

Q3: What is the THD value of AIKE AP200 alternator? Can it drive precision electronic equipment?

A: Alternator no-load THD < 2%, pure sine wave stable output with voltage fluctuation ≤±1%, fully compatible with medical equipment, PLC, frequency converters and all kinds of nonlinear precision loads.

Q4: What fuel consumption under different load ratios for AP200 Perkins genset?

A: 100% load: 41.2 L/h, 75% load: 30.9 L/h, 50% load: 20.6 L/h, data tested under standard 25℃ ambient condition.

Q5: What warranty term do you provide for AP200 generator set?

A: 15 months after shipment / 1 year after on-site installation / 1000 accumulated running hours, take the earliest expired term as standard warranty coverage.

Q6: Can I order silent canopy and ATS automatic transfer switch as options?

A: Yes, silent soundproof canopy, ATS dual power transfer switch, multi-unit parallel control panel and mobile trailer chassis are all available customized optional accessories.